Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros







Base de dados
Intervalo de ano de publicação
1.
Acta cir. bras ; 26(6): 530-534, Nov.-Dec. 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-604205

RESUMO

PURPOSE: To analyze pre-, intra- and immediate postoperative parameters of patients submitted to liver transplantation. METHODS: Eighty-three consecutive orthotopic liver transplants performed from January 2009 to July 2011 were analyzed. The patients were divided into 2 groups: A, survivors (MELD between 9 and 60) and B, non-survivors (MELD between 14 and 40), with 30.6 percent of group A patients being CHILD C, 51℅ CHILD B and 18,4℅ CHILD A. In group B ,32.1℅ of the patients were CHILD C, 42,9℅ CHILD B, and 25℅ CHILD A. All orthotopic liver transplantations were performed using the piggyback technique without a portacaval shunt. Systemic arterial pressure and serum ALT and AST levels were determined preoperatively and 5, 60 and 1440 minutes after arterial graft revascularization. Serum ALT and AST profiles were evaluated for seven days after surgery. RESULTS: Systemic arterial blood pressure levels, time of hot and hypothermic ischemia and time of graft implant were statistically similar for the two groups (p>0.05). Serum levels (U/L) of ALT and AST at the 5, 60 and 1440 minute time points after arterial revascularization of the graft were also similar for the two groups studied, as also were the serum ALT and AST profiles. CONCLUSIONS: No statistically significant difference in any of the parameters studied was detected between the two groups. Under the conditions of the present study and on the basis of the parameters evaluated, no direct relation was detected between the intraoperative period and the type of patient outcome in the two groups studied.


OBJETIVO: Analisar parâmetros do pré, intra e pós-operatório imediato de pacientes submetidos ao transplante de fígado. MÉTODOS: Foram analisados 83 transplantes ortotópicos de fígado realizados consecutivamente no período janeiro de 2009 a julho de 2011. Os pacientes foram dividos em dois grupos: A, survivors (MELD entre 16 e 60), e B, non-survivors (MELD entre 14 e 40) sendo que 30,6℅ dos pacientes do grupo A eram CHILD C, 51℅ CHILD B e 18,4℅ CHILD A. No grupo B, 32,1℅ dos pacientes eram CHILD C, 42,9℅ CHILD B, e 25℅ CHILD A. Todos os transplantes ortotópicos de fígado foram feitos com a técnica de piggyback sem "shunt" porto cava. Foram analisados os valores de pressão arterial sistêmica e os níveis séricos de ALT e AST, no pré-operatório, 5, 60 e 1440 minutos após revascularização arterial do enxerto. Avaliaram-se os perfis séricos da ALT e AST durante sete dias de pós-operatorio. RESULTADOS: Verificou-se que em ambos os grupos, os níveis de pressão arterial sistêmica, os tempos de isquemia normotérmica, hipotérmica e de implante do enxerto foram estatisticamente semelhantes (p>0,05). Os níveis séricos (U/L) de ALT e AST nos tempos de 5, 60 e 1440 minutos após a revascularização arterial do enxerto também foram semelhantes nos grupos estudados. Os perfis séricos da ALT e AST foram semelhantes nos dois grupos estudados. CONCLUSÕES: Não se verificou diferença estatisticamente significante entre todos os parâmetros estudados, em ambos os grupos. Nas condições do presente estudo, não se verificou relação direta do intra-operatório com o tipo de evolução (outcome) dos pacientes nos dois grupos estudados.


Assuntos
Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Alanina Transaminase/sangue , Aspartato Aminotransferases/sangue , Doença Hepática Terminal/cirurgia , Transplante de Fígado , Pressão Sanguínea , Brasil , Biomarcadores/sangue , Doença Hepática Terminal/enzimologia , Doença Hepática Terminal/mortalidade , Transplante de Fígado/mortalidade , Transplante de Fígado/estatística & dados numéricos , Período Perioperatório , Estudos Retrospectivos , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
2.
Acta cir. bras ; 25(2): 206-213, Mar.-Apr. 2010. graf, tab
Artigo em Inglês | LILACS | ID: lil-540498

RESUMO

Purpose: Standardization of a simple and low cost technique of exhaled breath condensate (EBC) collection to measure nitrite. Methods: Two devices were mounted in polystyrene boxes filled either with crushed ice/salt crystals or dry ice/crushed ice. Blood samples were stored at -70º C for posterior nitrite dosages by chemiluminescence and the Griess reaction. Results: a) The use of crushed ice/dry ice or salt revealed sufficient EBC room air collection, but was not efficient for patients under ventilation support; b) the method using crushed ice/salt collected greater EBC volumes, but the nitrite concentrations were not proportional to the volume collected; c) The EBC nitrite values were higher in the surgical group using both methods; d) In the surgical group the nasal clip use diminished the EBC nitrite concentrations in both methods. Conclusions: The exhaled breath condensate (EBC) methodology collection was efficient on room air breathing. Either cooling methods provided successful EBC collections showing that it is possible to diminish costs, and, amongst the two used methods, the one using crushed ice/salt crystals revealed better efficiency compared to the dry ice method.


Objetivo: Padronizar técnica simples e barata de coleta do condensado do ar exalado pulmonar (CEP) para medir nitrito. Métodos: Dois dispositivos foram montados em caixas de isopor e preenchidos com gelo picado/sal grosso ou gelo picado/gelo seco. Amostras de sangue foram armazenadas a -70º C para dosagem de nitrito por quimiluminescência e pela reação de Griess. Resultados: a) a utilização de gelo picado/gelo seco ou sal foi eficiente para a coleta em respiração espontânea, mas ineficiente durante ventilação mecânica; b) o método gelo picado/sal coletou volumes maiores, sem aumento proporcional do nitrito; c) os valores do nitrito foram mais elevados no grupo cirúrgico utilizando os dois métodos; d) no grupo cirúrgico com clipe nasal ocorreu diminuição do nitrito em ambos os métodos. Conclusões: A metodologia do condensado do ar exalado pulmonar (CEP) foi eficiente na coleta respirando em ar ambiente. Os dois métodos de congelamento foram eficientes mostrando que é possível diminuir os custos, e, entre os dois métodos utilizados, o uso de gelo picado/sal mostrou melhor eficiência quanto ao volume da coleta do CEP em comparação com o uso de gelo seco.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Testes Respiratórios/métodos , Nitritos/análise , Biomarcadores/análise , Testes Respiratórios/instrumentação , Estudos de Casos e Controles , Custos e Análise de Custo , Etilenodiaminas , Luminescência , Sulfanilamidas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA